FNIRSI® DPOX180H 2 Channel 180MHZ 2-IN-1 Digial Phosphor Oscilloscope
- 2 Channels Digital Phosphor Oscilloscope
- 2 in 1 Handheld Oscilloscope+ DDS Signal Generator
- 180Mhz Bandwidth 500MSa/s Sampling Rate
- Record depth 32kb
- Maximum measurement voltage ±400V
- 200mv/div-10v/div vertical sensitivity
- Support waveform image storage and export.
- Trigger function: auto/normal/single
- Effortless Usage: one-key-auto
- Seamless Operations: Enhanced Data Saving
Pairs well with
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
Shipping Information
Use this text to answer questions in as much detail as possible for your customers.
Customer Support
Use this text to answer questions in as much detail as possible for your customers.
FAQ’s
Use this text to answer questions in as much detail as possible for your customers.
Contact Us
Use this text to answer questions in as much detail as possible for your customers.
Notice
Product Details
Basic Specifications:
Introduction:
Display and Technology:
Functionality and Features:
Connectivity and Power:
Physical Dimensions:
Package Contents:
Warning Tips:
1. Electrical Safety:Always ensure that the device is used in accordance with electrical safety standards to prevent electric shock or damage to the equipment.
2.High Voltage: Exercise caution when working with high voltage signals. Make sure to use appropriate safety measures and protective gear to avoid injury.
3. Proper Grounding: Ensure that the oscilloscope is properly grounded to prevent electrical hazards and ensure accurate measurements.
4. Overloading: Avoid applying signals that exceed the specified input voltage range to prevent damage to the device.
5. Heat Dissipation: Allow the device to dissipate heat effectively by ensuring proper ventilation around the device during operation.
6. Firmware Updates: When performing firmware updates, ensure that the process is carried out correctly to avoid any potential disruptions or errors in the operation of the device.
7. Battery Usage: Follow the manufacturer's instructions for charging and using the battery to prevent overheating, fire, or explosion hazards.
8. Storage and Transportation: Store and transport the device carefully to prevent physical damage or exposure to extreme environmental conditions.
9. User Manual: Always refer to the user manual for proper usage instructions, safety precautions, and troubleshooting guidelines.
10. Maintenance: Regularly inspect and maintain the device to ensure optimal performance and safety. If any abnormalities are detected, discontinue use and seek professional assistance.
Dual Channel
Handheld Digital Oscilloscope
180MHz-3DB
2 In 1 Function : Signal Generator +Oscilloscope
FAQs
Please read our FAQs page to find out more.
Why can't the device be turned on after receiving it?
The power-on operation involves pressing the power button. If the device still cannot be turned on, it might indicate that the battery is depleted. Connect the provided USB cable to charge it; the power button will display red during charging. You can start the device once it's charged.
Why is there no waveform displayed during the test, only a straight baseline on the screen?
Please check whether the pause button is pressed. If not, press the [AUTO] button. If the issue persists, it may be due to the signal source having no signal output, or the probe line being short-circuited or open-circuited. Please use a multimeter to check the probe and verify whether the signal source is functioning normally.
Why is the voltage value zero?
Please adjust the vertical sensitivity and time base (sampling rate), or press [AUTO]. Ensure that a clear and complete cycle waveform is displayed on the screen, and that the top and bottom of the waveform are fully visible without clipping. At this point, the voltage value should be correct.
Why is there a significant offset between the baseline (0V) and the left arrow (0V indication) on the screen when there is no signal input?
First, pull out the probe, then perform system calibration once. After calibration is completed, the baseline will coincide with the arrow.
Why can't the oscilloscope capture sudden pulse waveforms or digital logic signals?
Adjust the trigger mode to Single trigger mode, then adjust the trigger voltage, time base, and vertical sensitivity. Finally, release the pause and wait for the arrival of the burst signal; it will automatically pause after being captured.