Tester di resistenza interna della tensione della batteria FNIRSI HRM-10

SPEDIZIONE GRATUITA OLTRE $ 30

Dettagli del prodotto

Tabella dei parametri
Please check the detail:
Specifiche di base:

- Device Name: FNIRSI "HRM-10"

- Type: Handheld high-precision battery internal resistance meter

- Measurement Method: True four-wire measurement

- Measurement Ranges:

- Voltage: 0 — ±100V (DC)

- Resistance: 0 — 200Ω

- Accuracy: ±0.5%

- Instrument Test Signal Frequency: AC 1KHz

- Rechargeable: Type-C interface (5V/1A)

- Built-in Battery: 1000mAh lithium battery

- User Calibration: Supported

Introduzione:

FNIRSI "HRM-10" is our company's first handheld high-precision attery internal resistance meter. It is a true four-wire measurement internal resistance

meter, designed with precision, convenient to carry. The device can automatically test internal resistance and voltage values simultaneously, with measurement results displayed on the screen. Users can also manually adjust the voltage and resistance range. The product features a sorting mode, automatically filtering the good and bad batteries based on user-set thresholds. It also supports historical records and exporting data tables of historical measurements.

Display e tecnologia:

- Screen: HD Color Screen

- Measurement Results Display: On-screen display

Funzionalità e caratteristiche:

- Measurement Modes:

- Automatic Testing of Internal Resistance and Voltage

- Manual Adjustment of Voltage and Resistance Range

- Sorting Mode: Automatically filters good and bad batteries based on user-set thresholds

- Historical Records: Supports historical records and exporting data tables of historical measurements

Connettività e potenza:

- Connectivity: Type-C Interface

- Power Input: 5V/1A

Dimensioni della confezione:

- Size: 158.7×80.5×28.4mm

- Weight: 225g

Contenuto del pacco:

- HRM-10 Host: 1

- Clip Test Line: 1

- Type-C Data Cable: 1

- User Manual: 1

- Packaging Box: 1

Manuale:
https://www.mediafire.com/file/3ml037lt1bzyxgi/
Suggerimenti di avvertimento:

1. Electrical Safety:Always ensure that the device is used in accordance with electrical safety standards to prevent electric shock or damage to the equipment.

2.High Voltage: Exercise caution when working with high voltage signals. Make sure to use appropriate safety measures and protective gear to avoid injury.

3. Proper Grounding: Ensure that the oscilloscope is properly grounded to prevent electrical hazards and ensure accurate measurements.

4. Overloading: Avoid applying signals that exceed the specified input voltage range to prevent damage to the device.

5. Heat Dissipation: Allow the device to dissipate heat effectively by ensuring proper ventilation around the device during operation.

6. Firmware Updates: When performing firmware updates, ensure that the process is carried out correctly to avoid any potential disruptions or errors in the operation of the device.

7. Battery Usage: Follow the manufacturer's instructions for charging and using the battery to prevent overheating, fire, or explosion hazards.

8. Storage and Transportation: Store and transport the device carefully to prevent physical damage or exposure to extreme environmental conditions.

9. User Manual: Always refer to the user manual for proper usage instructions, safety precautions, and troubleshooting guidelines.

10. Maintenance: Regularly inspect and maintain the device to ensure optimal performance and safety. If any abnormalities are detected, discontinue use and seek professional assistance.

Customer Reviews

Based on 124 reviews
95%
(118)
3%
(4)
2%
(2)
0%
(0)
0%
(0)
G
Goran T.
HRM-10

The%20first%20impression%20is%20positive%20and%20it%20refers%20to%20the%20appearance%20and%20quality%20of%20the%20instrument%20housing%20as%20well%20as%20the%20cables.%20I%20made%20some%20measurements%20on%20the%20batteries%20I%20have%20at%20home,%20but%20I%20will%20have%20the%20final%20assessment%20when%20I%20compare%20the%20measurements%20with%20a%20colleague%20who%20has%20a%20professional%20instrument.

B
Bradly W.

Appliance received, perfect design, accurate, reliable and at a very affordable price. Thanks to the developers, fnirsi

Z
Zoe S.

Received the tester in Ukraine, the packaging is intact, the device is fully charged and working. Everything is OK. Checked the tester-all functions are working.

B
Beth W.

Goods of the goods of the goods of the goods. Sell the same product. I went three days. I recommend the product and the seller.

S
Sheila A.

Everything is fine. I will sell my daughter for a box for a dodatkov. Moisture, the packaging was saved. The Prad itself is of the Yakish crushings, it's good, I 've got the firmware. O on the site fnirsi at the group download. The probes are not for good, you can buy the alternative (ale roz'm on alternative hiddmore for everything you will get it). Tester I am a proxit. My daughter. Everything is OK. The big thanks for seller.

SPEDIZIONE GRATUITA

Domande frequenti

Ti invitiamo a leggere la nostra pagina delle domande frequenti per saperne di più.

Problema di regolazione zero

   Se i due clip sono in cortocircuito e non leggono zero ma mostrano x,xxx mΩ, è normale. Il valore minimo (che potrebbe essere zero o molto vicino allo zero) viene visualizzato solo quando le due clip sono perfettamente a contatto. Non importa se non è zero. Durante la misurazione, il programma interno ha già calcolato il valore teorico, quindi la precisione non viene influenzata e la calibrazione dello zero non è necessaria.

La batteria deve essere completamente carica per la misurazione?

   La resistenza interna di una batteria solitamente differisce quando è completamente carica rispetto a quando è quasi scarica. Nello specifico la resistenza interna cambia a seconda dello stato di carica:

   - Stato completamente carico: quando la batteria è completamente carica, la resistenza interna è generalmente inferiore perché le reazioni chimiche all'interno della batteria sono più attive, consentendo un trasferimento più semplice della carica.

   - Stato di carica bassa: quando la batteria è quasi scarica, la resistenza interna generalmente aumenta. Man mano che la batteria si scarica, le reazioni chimiche interne diventano meno attive, rendendo più difficile il trasferimento della carica, il che porta ad un aumento della resistenza interna.

I risultati della misurazione sono instabili o imprecisi

   Risultati di misurazione instabili o imprecisi possono essere dovuti a uno scarso contatto tra le clip di test e la batteria, all'instabilità della batteria sottoposta a test, all'ossidazione degli elettrodi o all'interferenza di un forte campo elettromagnetico nell'ambiente circostante.

La resistenza interna misurata è maggiore della resistenza interna della batteria

   Quando si misurano batterie ad alta capacità (con resistenza interna molto bassa), è fondamentale prestare attenzione alla posizione delle clip. La resistenza interna degli elettrodi della batteria o dei cavi di collegamento è spesso maggiore di quella della batteria stessa. Pertanto, quando si misurano batterie a bassa resistenza, assicurarsi che le clip siano posizionate correttamente e facciano un buon contatto.

Quali tipi di batterie possono essere misurate?

   L'HRM-10 può misurare qualsiasi tipo di batteria, comprese batterie al litio, batterie al piombo-acido, batterie al nichel-cromo e batterie a secco.

Perché la misurazione della resistenza interna può determinare la qualità della batteria?

   La resistenza interna della stessa tipologia di batteria aumenta e la capacità diminuisce nel tempo con l'uso. Minore è la resistenza interna, maggiore è la capacità di carico; in caso contrario, potrebbe surriscaldarsi o non funzionare. Le batterie con prestazioni migliori invecchiano più lentamente, mentre quelle di qualità inferiore invecchiano più rapidamente.

Qual è la resistenza interna tipica di una batteria 18650?

  La resistenza interna di una nuova batteria al litio 18650 è generalmente inferiore a 50 milliohm. Quelli di alta qualità sono circa 20 milliohm, quelli medi intorno a 30 milliohm e quelli più scadenti sono superiori a 50 milliohm.

Quale capacità delle batterie può essere misurata?

   È possibile misurare qualsiasi capacità delle batterie, indipendentemente dalle dimensioni, purché la resistenza interna sia compresa tra 0 e 200 ohm e la tensione sia inferiore a 100 V.

È possibile misurare online la resistenza interna e testare l'alimentazione dell'UPS?

   Il test online è possibile senza compromettere il funzionamento della batteria, pertanto le batterie nei sistemi UPS possono essere testate senza interruzioni.

Non hai trovato la risposta?

Non esitate a contattarci